“Quantifying unintended exposure to high tidal volumes from breath-stacking dyssynchrony in ARDS: the BREATHE criteria,” Intensive Care Medicine, 2016, USA
Note: I am focusing on only one aspect of this paper, see the comments section for more details
Question: Using novel diagnostic criteria, how often does breath-stacking dyssynchrony (BSD) occur in pts with ARDS?
Study Type: Prospective observational study at 2 US hospitals
Study Population: Adult pts with ARDS placed on mechanical ventilation within the previous 24 hours were eligible provided they were ventilated in the assist-control mode. Exclusion criteria included chronic mechanical ventilation, neuromuscular disease compromising spontaneous ventilation, and impending withdrawal of full supportive care
Study Groups: Airflow and pressure were continuously recorded for 72 hours, coded by an analog-digital converter, and read directly into an analysis program. The flow-time waveform was integrated to calculate cumulative tidal volume change over consecutive machine inspiratory cycles. BSD was identified using the BREATHE criteria (consecutive inspiratory cycles + expiratory times <1 sec + expiratory volume between inspiratory cycles at least 2mL/kg PBW less than first inspiratory cycle volume + •120% set inspiratory time {for pressure-targeted breaths} + BSD TV •2mL/Kg PBW above intended TV) (essentially saying the pt inspires twice before fully exhaling the first breath). Medication administration and ventilator management were directed by the ICU team who were blinded to study analysis.
Primary Outcome: BSD as measured by the BREATHE criteria
Results: 33 pts were enrolled. Notable pt characteristics: mean age (57), shock (91%), pneumonia (83%), duration of MV prior to enrollment (16 hrs), death before discharge or day 28 (27%). Vent characteristics: VC+ (volume-targeted pressure control) (79%), VC (typical volume-cycled ventilation with a set flow rate) (21%), set TV (6 mL/kg PBW), RR (25), PEEP (10), FiO2 (50%), P/F (107). 1,841 hrs were recorded and 2,166,076 breaths were analyzed (80% without neuromuscular blockage). Observed BSD frequency was 27 (7-59) breaths/hr, peak hourly BSD frequency was 170 (55-394) breaths/hr. BSD frequency was sustained for more than 60 breaths/hr during 18% (1-37) of hrs recorded without NMB. TV during BSD was 11.3 (9.7-13.3) mL/kg PBW. Peak airway pressure minimally increased with BSD.
Caveats: Small sample size, 743 hours not recorded or included for various reasons, does not establish any connection between BSD and outcomes including ventilator-induced lung injury.
Take-home Point: Among pts with ARDS ventilated in assist-control mode, breath-stacking dyssynchrony occurs and exposes pts to potentially injurious tidal volume.
Commentary
- The BREATHE criteria are fine, but for residents easier to just remember that BSD is “inspiratory flow triggered before complete expiration” (i.e., the pt is triggering a 2nd breath before fully exhaling the first).
-
I have purposely ignored one of the main aspects of this study: comparing the BREATHE criteria to other methods of measuring BSD. Unless you are really into reading about ventilator dyssynchrony, this part of the paper is less interesting than the more basic message that BSD occurs (sometimes quite often) in AC modes.
-
This paper is a nice reminder that when you are setting a tidal volume in either VC or VC+, this does not guarantee that this is the volume your pt will receive before exhaling. You may think your pt is receiving “lung-protective ventilation,” but frequent episodes of BSD may cause your pt to receive very large TVs (in the above study, an average Vt of 11 mL/kg PBW). These results highlight the importance of looking at ventilator waveforms in your pts and frequently evaluating synchrony.
-
Whether decreasing BSD improves outcomes remains to be seen. This is one of the proposed mechanisms by which early neuromuscular blockade may improve outcomes in ARDS but more studies are needed to prove this connection.